Method development and validation of RP-HPLC method for simultaneous determination of Lamivudine and Zidovudine
Abstract
A rapid, sensitive and specific RP-HPLC method involving UV detection was developed and validated for determination and
quantification of Lamivudine and Zidovudine. Chromatography was carried out on
a pre-packed AltimaC18 5μ (150*4.6mm) column using filtered and degassed
mixture of Ammonium acetate buffer:Methanol (80:20) as mobile phase at a flow
rate of 1.0ml/min and effluent was monitored at 270nm. The method was validated
in terms of linearity, precision, accuracy, and specificity, limit of
quantification and limit of detection. The assay was linear over the concentration
range of Lamivudine and Zidovudine was 37.5mcg-112.5mcg/ml and 75mcg to 225mcg/ml
respectively. Accuracy of the method was determined through recovery studies by
adding known quantities of standard drug to the pre analyzed test solution and
was found to be 98.50%-99.9% and 98.30%-100.10% within precision RSD of 0.71
and 0.82 for Lamivudine and Zidovudine respectively. The system suitability
parameters such as theoretical plates and tailing factor were found to be
3189.33, 1.12 and 7852.83, 1.05 respectively for Lamivudine and Zidovudine

Comments
Post a Comment